The wide-spread popularity and acceptance of water birth pools as a standard part of the maternity care package necessitated the development of guidelines & regulations to define standards and ensure they’re met.

The Water Birth Safety Initiative (WBSI) calls for development of international standards modelled on the UK’s so that women the world over can benefit from the use of water for labour and birth safeguarded from risk.

The WBSI calls for the implementation of stricter protocols and sets forth recommendations for equipment standards.

The guidelines set forth in the WBSI are intended to serve as a framework of standards for birth pool suppliers, hospitals and midwives to work with to establish  safe codes of practice.

Guidelines for Water Birth Pools Installed in Hospital

Water is more prone to bacteria growth after it leaves the public water distribution system and enters a building’s plumbing.

There it finds warmer temperatures, stagnation, and smaller pipes, valves and fittings.

Biofilm that forms on valves and fittings and pipe walls not only feeds bacteria but also protects them from the hot water and chlorine that typically would kill free-floating organisms.

Large systems with complex piping networks — like those found in hospitals, hotels and large apartment buildings — are especially prone to bacteria growth.

Water Birth Pools that are installed in hospitals have the benefit of being maintained by staff to ensure that protocols are established, met and maintained.

Consideration and due diligence with regard to the prospective purchase of water birth pools and the assessment of pools already in use needs to be taken to ensure that the associated plumbing and electrical systems meet relevant safety standards.

The 7 sins of water safety

To ensure high standards are met it is strongly advised that you do not use a water birth pool that has any of these features:

  1. Overflow drains
  2. Internal water inlets
  3. Hand-held showers
  4. Systems with flexible hoses or extended pipes
  5. Integral or secondary plumbing systems
  6. Any type of recirculating or pumped water systems such as whirlpool, jacuzzi, spa, bubbling, filtering etc
  7. Heating systems

1) Overflow drains

Overflow drains harbour bacteria and can serve as a conduit for cross infection.

Regulations are very clear on this point – overflow drains should not be installed on water birth pools as they constitute a constant infection control risk much more significant than the possible risk of damage due to water overflowing

Some digital taps on the market can be set for filling time thus obviating the risk of the pool overflowing.

2) Internal water inlets

Internal water inlets act in place of taps to fill the pool.

They are installed on the inside of the pool just above the water line and connected with pipework to a thermostatic valve.

If the water level rises there is a high risk of back flow enabling bacteria to enter the system creating a risk of cross infection

3) Handheld showers

Handheld showers present a significant infection control risk due to the fact that they can fall in the pool and be contaminated with bacteria that could breed and be passed on next time the shower is used.

Department of Health regulations clearly stipulate that handheld showers and bath/shower mixers are not installed for use with water birth pools. 13

It must not be possible to submerge the showerhead in the water due to risk of cross infection.

4) Systems with flexible hoses or extended pipes

Systems that employ flexible piping, have branch pipes or hold stagnant water present a potential hazard and must not be used with water birth pools.

It is impossible to clean, disinfect or monitor these systems.

They have been proven to be a source of Legionella and Pseudomonas.

Weekly flushing recommendations cannot be executed with such systems, and the effectiveness of this cannot be monitored due to the inacessibility of the closed system.

5) Integral or secondary plumbing systems

Integral, secondary or proprietary plumbing systems are fitted to some water birth pools.

As these systems can employ flexible and non-flexible piping, overflow drains, handheld showers and are often pumped or recirculating they present a significant infection control risk and should be banned from use.

Not only do secondary or integral plumbing systems present unacceptable risks, they are impossible to clean, disinfect or monitor and therefore present an extremely high and unacceptable infection control risk.

They must not be present on pools used for labour and birth.

6) Recirculating or pumped water systems

Recirculating or pumped water systems such as whirlpool, jacuzzi, spa, bubbling, filtering etc. have the perfect environmental conditions to be a potential source for the growth of microorganisms, including legionella bacteria and must not be installed on water birth pools.

Water systems that are able produce aerosols represent the highest levels of risk.

Aerosols can be generated very easily when the water surface is broken -for example, by falling water droplets, splashing, or by bubbles breaking at the surface.

Once introduced to artificial water systems, Legionella can thrive in warm water (30 – 35 °C) and has been shown to be present on flexible seals and metal surfaces within plumbing systems used in domestic potable water supplies.

Inadequately maintained spa pools (birth pools with pumped or recirculating systems) provide ideal conditions to support the growth of legionellae and other microorganisms, which may then become aerosolised and subsequently inhaled.

7) Heating systems

Heating systems for water birth pools are not necessary and present unacceptable infection control risks.

There are two types of heating systems in use:

1. Recirculating system with a heat exchanger

Water is pumped out of the pool and through a heat exchanger and then flows back into the pool.

These systems present one of the highest infection control risks and should not be installed on a water birth pool under any circumstances. (covered by points 4, 5 and 6 above).

2. Electric heating systems

Similar to under floor heating found in homes do not present an infection control risk.

But, they do present an unacceptable health and safety risk and should therefore not be installed in water birth pools.

These systems consist of a network of cables embedded in the fabric of the birth pool that are attached to the power supply through a thermostat.

The heat is transmitted from the cables through the floor of the pool and then transferred to the water.

The inherent problem with these systems is that the water is relied on to take the heat away from the material.

If a woman remains motionless the heat becomes concentrated and a “hotspot” develops which can result in the woman being burned.

Recommendations

Plumbing for filling and emptying water birth pools should be simple, straight forward and kept to the minimum.

A set of taps (see below) mounted on the wall 15cm above the rim and a drainage system similar to that of a normal bath is all that is required.

Rim mounted taps present two areas of risk:

1. Women may hit their head on taps that are mounted on the rim of the pool causing injury.

In the throes of labour a woman is not as cognisant of her surroundings as she normally is.

She needs to be protected from the potential harm that could result from hitting her head or other part of her body on the spout.

2. Risk to the taps and pool caused by the labouring woman grabbing onto the spout for support could easily cause damage to the fitting or fabric of the pool.

Water Birth Pools should be filled directly from the hospitals main water supply through a ¾ Thermostatic Mixing Valve (TMV). We suggest that you consider the Rada Sense Bath T3(or similar) as it is a digital tap that enables you to programme the water temperature and fill time

To kill legionella and other bacteria, water in hospitals systems is heated to 60 – 80 °C.

Water temperature entering the birth pool should be limited by the TMV to 44 °C to prevent scalding.

The added benefit of using a TMV connected directly to the hospitals main water supply is that it can be set to automatically flush itself of stagnant water twice a day and be thermally disinfected periodically.

The use of a TMV ensures a safe water supply.

Digital thermostatic mixing valves with enhanced thermal performance that incorporate these features are ideal:

1) Programmable control to accurately mix and maintain the temperature of the water flowing into the birth pool and limit the temperature of the water to 44 °C to prevent scalding.

2) Programmable fill duration to fill the pool to the desired depth and then turn off.

This is important as water birth pools are not allowed to have overflow drains installed and this feature will prevent the pool from overflowing when unattended.

3) Programmable duty flushing to ensure that water does not stagnate within the tap and associated pipe work, effectively controlling the multiplication of legionella & other bacteria in infrequently used outlets.

4) Programmable high-temperature thermal disinfection to destroy the proteins in viruses and bacteria and render them as dead or inert.

Thermal disinfection works by achieving a moist heat which is set at a specific temperature for a set amount of time.

Viruses and bacteria are very sensitive to heat and they will die if exposed to higher temperatures.